About this item
The apparatus of electropuncture therapy "Vityaz AET-01" is intended for superficial transcutaneous electrical stimulation of human biologically active points (acupuncture points) and pain zones with low-frequency electric current without violating the integrity of the skin.
 
The device is used to treat various diseases, as well as in cases where it is necessary to obtain an analgesic effect in case of pain syndromes.
 
Small dimensions, weight and autonomous power supply make it possible to use it not only in inpatient and outpatient settings, but also in cases of emergency treatment at home.
 
Attention! Batteries are not included.
 
Purpose:
 
- superficial transcutaneous electrical stimulation of human biologically active points by low-frequency electric current without skin puncture and damage to body tissues;
- relief of traumatic or chronic pain;
removal of fatigue;
-Helps with insomnia.
 
Application area:
 
-therapy;
-stomatology;
-ENT diseases.
 
Advantages:
 
- safe;
-easy to use;
-has no side effects;
- meets the requirements for use in medical institutions;
- applicable at home.
 
Contraindications:
 
-cardiovascular diseases with cardiac arrhythmias;
- acute purulent inflammatory processes;
-increased body temperature;
-bleeding and bleeding in the affected area;
pregnancy;
- skin damage;
- thrombophlebitis;
- benign and malignant neoplasms;
-blood clotting disorders;
-active rheumatism, tuberculosis process;
- congenital lesion of the central nervous system;
- the presence of metal in the impact zone;
-individual intolerance to electric current;
-exhaustion.
 
Specifications:
 
-Maximum output pulse amplitude - 300±50V.
-Duration of output pulses - 50±10 microseconds.
- Frequency of output impulses - 20±6 Hz.
-Maximum current consumption - 10 mA.
- Power supply, V - 9 (battery).
Weight, not more than - 0.3 kg.
Overall dimensions - 185*60*60 mm.